Air Cooled Water Chiller for Blow Production Line

Air Cooled Water Chiller for Blow Production Line

Basic Information:

SIC-A-R2 series are applicable for cooling moulds to reduce products molding cycle time, also they are used in the cooling of blowing machine relative parts in order to get quality products.


Product Detail

Product Tags

Features of SHINI Air Cooled Water Chiller

1. Cooling range 7-25℃; Stainless steel inculated water tank.
2. Equipped with anti-freeze thermostat.
3.
Adopt ozone-friendly refrigerant R410A, used to improve coefficient of performance(COP).
4. Refrigerant loop controlled by high and low pressure switches to ensure stable operation.
5. Comppressor and pump overload protection.
6. Adopt precise high-precision temperature controller with an accuracy of ±1℃。
7. Single compressor system series are equipped with low pressure pump, and model with two or more systems are equipped with medium pressure pump.
8. All adopt well known and quality compressors.
9. Adopt fin style condenser design. Without any need of cooling water for excellent heat transfer and rapid cooling.

Parameters of SIC-A-R2 Series(50Hz)

Hautek will recommend you proper air coolled chiller according to the model of your blowing machine.

Model SIC-7.5A
-R2
SIC-12A
-R2
SIC-18A
-R2
SIC-24A
-R2
SIC-28A
-R2
SIC-38A
-R2
SIC-48A
-R2
SIC-58A
-R2
SIC-75A
-R2
Refrigerant Capacity(1) kw 7.5 12 18 24 28 38 48 58 75
Refrigerant Capacity(2) kw 9.5 14 24 32 38 45 64 76 90
Compressor Type Scroll
Power (kw) 2.9 4.2 6.4 8.72 9.36 12.25 17.44 18.72 24.86
Refrigerant Filling Volume (kg) 3.5 5 5.5 5.5 9 12.5 7.5x2 8x2 8x2
Control Mode Thermostatic expansion valve
Type R410A
Evaporator Type Tube-in-shell style
Condenser Type Fin style
Blower (KW) 0.19 0.55 2x0.23 2x0.385 2x0.6 2x0.78 2x1.03 2x0.85 2x1.92
Water tank capacity(L) 30 30 65 65 80 80 186 186 230
Pump(4) Power(KW) 0.75/0.75/1.1 1.1/1.1/1.1 1.1/1.5/2.2 -/1.8/2.4 -/3.0/4.0
Pump flow(L/min) 21.5 34.4 51.6 68.8 80.3 108.9 137.6 166.3 215
Working Pressure(kgf/cm2)(3) 3.3/3.7/4.5 3.2/3.5/4.4 2.8/4.1/4.9 2.7/2.35/4.5 3.1/3.9/4.9 2.4/3.8/4.6 -/3.4/4.5 -/3.2/4.3 -/3.5/4.1
Total power Total Power(KW) (5) 3.8/3.8/4.2 5.5/5.5/5.9 7.8/7.8/7.8 10.6/10.6/10.6 11.7/12/12.8 14.9/15.3/16 -/21.3/21.9 -/22.2/22.8 -/31.7/32.7
Pipe coupling(inch) Chilled water outlet 1 1 1/2 2 2 1/2
Chilled water inlet 1 1 1/2 2 2 1/2
Water tank drainage port 1/2 1
Water tank overflow port 1/2
Protective devices Compressor Overload relay
Pump Overload relay
Refrigerant circuit High and low pressure switch/Anti-freeze switch
Cooling water circuit By-pass valve/Water level switch(option)/Flow switch
Power(VAC)(6) 3Phase, 400VAC, 50Hz
Measures exchange 1kw=860 kcal/hr 1RT=3.024 kcal/hr 10.000 Btu/hr=2.520 kcal/hr

Note:  1) Refrigeration capacity 1 is based on the flow of 0.172m3/(h.k.W), the chilled water outlet temperature of 7℃ and the environment temperature 35℃.
           2) Refrigeration capacity 2 is based on the flow of 0.172m3/(h.k.W), the chilled water outlet temperature of 15℃ and the environment temperature 25℃.
           3) It is the working pressure of water pump when negative pressure of inlet water is 0.                                    

           4) Low pressure pump is for domestic and Southest Asia export, customers can change for medium pressure pumps(use P for short; e.g.:SIC-and
            A-R2-P) or high pressure pumps(use HP for short; e.g.:SIC-and A-R2-HP), specific parameters in turn as shown above.                                    
           5) Pump power is included in total power.                                    
           6) Special orders of machine voltage can be acceptable according to customers's request.                                    
           7) The air-cooled water chiller is applicable to the conditions under the environment temperature of 43℃.       

Parameters of SIC-A-R2 Series(60Hz)

Hautek will recommend you proper air coolled chiller according to the model of your blowing machine.

Model SIC-12A-R2 SIC-24A-R2 SIC-28A-R2 SIC-38A-R2 SIC-48A-R2 SIC-58A-R2 SIC-75A-R2 SIC-100A-R2 SIC-114A-R2
Refrigerant Capacity(1) kw 15 30 35.5 45 60 70 90 122 136
Refrigerant Capacity(2) kw 17.5 37.5 41 48 75 82 96 133.5 144
Compressor Type Scroll
Power (kw) 5.28 10.2 11.73 14.8 20.4 23.76 29.6 39.8 44.4
Refrigerant Filling Volume (kg) 5 5.5 9 12.5 7.5x2 8x2 8x2 7.8x2+6.8 8.7x3
Control Mode Thermostatic expansion valve
Type R410A
Evaporator Type Plate evaporator
Condenser Type Fin style
Blower (KW) 0.91 2x0.57 2x0.91 2x1.1 2x2.2 2x2.2 2x2.2 2x2.2+2.2 3x2.2
Water tank capacity(L) 50 85 150 150 180 200 270 400 400
Pump(4) Power(KW) 0.75/1.5 1.1/1.5 2.2/3.0 2.2/3.0 3.0/3.0 3.0/3.0 5.5/5.5 5.5/5.5 5.5/5.5
Pump flow(L/min) 43.1 86.2 102 129.3 172.3 201.1 258.5 350.4 390.7
Working Pressure(kgf/cm2)(3) -/3.1/5.1 -/3.0/4.2 -/2.7/4.1 -/2.5/3.9 -/4.5/5.6 -/3.9/4.8 -/2.8/2.8 -/4.5/4.5 -/4.1/4.1
Total power Total Power(KW) (5) -/6.9/7.6 -/12.4/12.8 -/15.7/16.5 -/19.2/20 27.8 31.1 39.5 51.9 56.5
Pipe coupling(inch) Chilled water outlet 1 1 1/2 2 2.5
Chilled water inlet 1 1 1/2 2 2.5
Water tank drainage port 1/2 1/2 1/2 1/2 1 1 1 1 1
Water tank overflow port 1/2 1
Protective devices Compressor Overload relay
Pump Overload relay
Refrigerant circuit High and low pressure switches/Anti-freeze switch
Cooling water circuit By-pass valve/Water level switch(option)/Flow switch
Power(VAC)(6) 3Phase, 230/400/460/575VAC, 60Hz
Measures exchange 1kw=860 kcal/hr 1RT=3.024 kcal/hr 10.000 Btu/hr=2.520 kcal/hr

Note: 

           1) Refrigeration capacity 1 is based on the flow of 0.172m3/(h.k.W), the chilled water outlet temperature of 7℃ and the environment temperature 35℃.
           2) Refrigeration capacity 2 is based on the flow of 0.172m3/(h.k.W), the chilled water outlet temperature of 20℃ and the environment temperature 30℃.
           3) It is the working pressure of water pump when negative pressure of inlet water is 0.
           4) Low pressure pump is for domestic and Southest Asia export, customers can change for medium pressure pumps(use P for short; e.g.:SIC-and A-R2-P)
           or high pressure pumps(use HP for short;e.g.:SIC-and A-R2-HP), specific parameters in turn as shown above
           5) Pump power is included in total power.
           6) Special orders of machine voltage can be acceptable according to customers's request.
           7) The air-cooled water chiller is applicable to the conditions under the environment temperature of 43℃.



RELATED PRODUCTS